Table 2: Summary of TLS performance indicators
W200 U50 U90 EPU56 SWLS SW60 IASWA IASWB IASWC Facility Status
Type hybrid hybrid hybrid pure SC SC SC SC SC
λ (mm) 200 50 90 56 N/A 60 61 61 61
Photon energy 800-15k 60-1.5k 5-500 80-1.4k 2k-38k 5k-20k 5k-20k 5k-23k 5k-20k
(eV)
B max (Tesla) 1.8 0.64 1.245 0.67(0.45) 6 3.2 3.1 3.1 3.1
Installation 12/1994 03/1997 04/1999 09/1999 04/2002 01/2004 12/2005 06/2009 02/2010
ACTIVITY REPORT 2016
Location sec. 5 sec. 3 sec. 6 sec. 2 sec. 1 sec. 4 arc sec. 6 arc sec. 2 arc sec. 4
monthly beam stability index of
Table 3: Summary of TLS performance indicators
TLS; it was satisfactory all year. The
Scheduled MTBF Beam scheduled user time, beam avail-
Year user time Availability Operating stability ability, beam stability index 0.1%,
mode
(hour) (hour) ΔI/I 0 < 0.1% and MTBF of each quarter in 2016
2003 5017 97.2% 313.6 decay 86% are shown together in Fig. 3; the
2004 4235 97.5% 132.3 decay 85% accelerator performance obviously
2005 4576 96.8% 81.7 decay/top-up 76% greatly improved since mid 2015
2006 5552 96.7% 40.8 top-up 81.3% and continued well in 2016.
2007 5219 98.1% 85.6 top-up 98.1%
2008 5726 97.9% 112.3 top-up 98.5% Replacement and improve-
2009 5402 97.9% 77.2 top-up 89.2% ment of main components
2010 5286 97.4% 81.3 top-up 82.1%
2011 5818 95.9% 55.4 top-up 89.4% Linac:
2012 5197 98.1% 44.8 top-up 91.4% • Linac klystron filament was re-
2013 5178 99.5% 140 top-up 95.5% placed with a new power-supply
2014 5645 99.4% 182.1 top-up 94.1% component.
2015 5327 98.7% 84.6 top-up 87.7%
2016 5526 98.2% 100.5 top-up 97.5% Power supplies of magnets:
• The circuit performance for noise
rejection of the TLS kicker was
improved.
• A full-sine-wave power supply
for the septum magnet was
implemented.
Instruments and controls:
• A second power-amplifier loop
on the vertical transverse-feed-
back system was upgrated to
enhance the feedback power.
• EPICS (experimental physics and
industrial control system) control
interfaces for the injection wave-
form display were updated.
Lattice:
Fig. 2: Summary of beam stability index of 0.1%, availability and MTBF of TLS from 2006 • The chromaticity of storage ring
to 2016.
was minimized.
h and 97.5%, respectively. Once an original component of old type aged Environmental monitor:
to show poor performance, it was upgraded to a new module as soon as • Ethernet cameras inside the
practicable. For example, the power supplies of the quadrupole magnets shielding tunnel for remote
were all replaced with new ones, the same modules as used for TPS. The monitoring and recording were
beam performance then gradually improved. Illustrated in Table 4 is the installed.