The accumulated downtime of each subsystem is shown in Fig. 5, with 99.73 h in total. Together with the trip
events listed in Table 5, it is shown that some trip events resulted in a long downtime. For example, a single cryo- Facility Status
genic event took about 6 h to effect a system recovery; this instance indicates the importance of great reliability
of these critical subsystems. (Reported by Chang-Hor Kuo)
ACTIVITY REPORT 2016
Fig. 4: An event of partial beam loss recorded with a rapid diagnostic system, in which an abnormal timing trigger for kicker waveform
was caught.
Fig. 5: Downtime of each subsystem in 2016.