| Overview |
The Life Sciences Research Facilities at NSRRC (LifeNSRRC) provide
multiple synchrotron-based experimental techniques for users to
study demanding scientific problems. These techniques include x-ray
diffraction, x-ray scattering, x-ray spectroscopy, micro-spectroscopy,
synchrotron radiation circular dichroism, and micro-imaging. We also provide professional discussions and
substantial user support; therefore, both experienced and non-experienced
users are all welcome to use these facilities through the NSRRC
proposal submitting
procedure.
Following list the techniques and the related beamlines currently
provided by LifeNSRRC. Click on the technique or beamline name to
get more detailed information about the specific facility.
- Biological
Crystallography (BX, MX, PX)
Beamline
|
Energy Range
(keV) |
Beam Size
(mm) |
Flux (p/s) |
Detector |
Technique |
| BL13B1 |
6.5-19 |
0.2 |
4x1011 |
Q-315 CCD |
MAD, Monochromatic |
| BL13C1 |
12.7, 13.5 |
0.2 |
4x1010 |
Q-210 CCD |
Monochromatic |
| BL12B2 |
7-23 |
0.25 |
6x1010 |
Q-4R CCD |
MAD, Monochromatic |
- X-ray
Absorption and Fluorescence Spectroscopy (XAS)
Beamline
|
Energy Range
(keV) |
Beam Size
(mm) |
Flux (p/s) |
Detector |
| BL17C1 |
5-14 |
6(H)x2(V) |
5.0x1010 |
13-Element Ge SSD, Lytle Detector,
Ion Chambers |
- Small
Angle X-ray Scattering from Non-Crystalline System (SAXS)
Beamline
|
Energy Range
(keV) |
Beam Size
(mm) |
Flux (p/s) |
Detector |
| BL17B3 |
6-14 |
0.5 |
2x1010 |
MWPC, FujiFilm IP |
BL23A1 (Constructing) |
5-23 |
0.5 |
1.4x1011(DCM)
2.8x1012(DMM) |
Mar165CCD, MWPC, FujiFilm
IP |
- Membrane X-ray
Scattering and Diffraction (Membrane Scattering)
Beamline
|
Energy
Range
(keV) |
Beam Size
(mm) |
Flux (p/s) |
Detector |
| Bl13A1 |
12 keV |
0.2(V)x0.8(H) |
6x1010 |
Bicron Detector, Area Detector |
- X-ray Diffraction
from Biological Fiber and Powder (Fiber Diffraction)
Beamline
|
Energy
Range
(keV) |
Beam Size
(mm) |
Flux (p/s) |
Detector |
| BL01C2 |
12-33 |
1 |
1.4x1010 |
Mar345 Imaging Plate |
- Microscopy
and Imaging
Beamline
|
Energy
Range
(keV) |
Beam Size
(mm) |
Flux (p/s) |
Technique |
| BL01A1 |
4 |
18(H)x9(V) |
1x1012 |
Micro Computed Tomography and MRI |
| BL01B1 |
8-11 |
1(H)x0.5(V) |
3x1011 |
Transmission X-ray Microscopy |
Beamline
|
Energy
Range
(cm-1) |
Beam Size
(µm) |
Flux (p/s) |
Technique |
| BL14A1 |
4000-650 |
10(H)x13(V) |
2×1010 |
Infrared Microspectroscopy |
- Bio-Sensor Fabrication
and Characterization
Beamline
|
Energy
Range
(keV) |
Beam Size
(mm) |
Flux (p/s) |
Power Density
(mW/cm2) |
Technique |
| BL18B1 |
0.5-3.0 |
150(H)x10(V) |
3x1011 |
- |
LAGA |
| BL19A1 |
0.8-2.0 |
5(H)x20(V) |
- |
65 |
Lithography |
- Synchrotron Radiation Circular Dichroism (SRCD)
Beamline
|
Energy
Range
(keV) |
Beam Size
(mm) |
Flux (p/s) |
Technique |
| BL04B1 |
4-40 |
2(H) x 1(V) |
5x109 |
Vacuum Ultraviolet Circular Dichroism |
|
|